Systematic reviews including this primary study

loading
2 articles (2 References) loading Revert Studify

Systematic review

Unclassified

Journal The Cochrane database of systematic reviews
Year 2023
Loading references information
BACKGROUND: Glaucoma is an optic neuropathy that leads to visual field defects and vision loss. It is the second leading cause of irreversible blindness in the world. Treatment for glaucoma aims to reduce intraocular pressure (IOP) to slow or prevent further vision loss. IOP can be lowered with medications, laser, or incisional surgery. Trabeculectomy is a surgical approach which lowers IOP by shunting aqueous humor to a subconjunctival bleb. Device-modified trabeculectomy techniques are intended to improve the durability and safety of this bleb-forming surgery. Trabeculectomy-modifying devices include the Ex-PRESS, the XEN Gel Stent, the PreserFlo MicroShunt, as well as antifibrotic materials such as Ologen, amniotic membrane, expanded polytetrafluoroethylene (ePTFE) membrane, Gelfilm and others. However, the comparative effectiveness and safety of these devices are uncertain. OBJECTIVES: To evaluate the benefits and harms of different devices as adjuncts to trabeculectomy on IOP control in eyes with glaucoma compared to standard trabeculectomy. SEARCH METHODS: We used standard, extensive Cochrane search methods. The latest search was August 2021. SELECTION CRITERIA: We included randomized controlled trials in participants with glaucoma comparing device-modified trabeculectomy techniques with standard trabeculectomy. We included studies that used antimetabolites in either or both treatment groups. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. Our primary outcomes were 1. change in IOP and 2. mean postoperative IOP at one year. Our secondary outcomes were 3. mean change in IOP from baseline, 4. mean postoperative IOP at any time point, 5. mean best-corrected visual acuity (BCVA), 6. visual field change, 7. quality of life, 8. proportion of participants who are drop-free at one year, 9. mean number of IOP lowering medications at one year, and 10. proportion of participants with complications. MAIN RESULTS: Eight studies met our inclusion criteria, of which seven were full-length journal articles and one was a conference abstract. The eight studies included 961 participants with glaucoma, and compared two types of devices implanted during trabeculectomy versus standard trabeculectomy. Seven studies (462 eyes, 434 participants) used the Ex-PRESS, and one study (527 eyes, 527 participants) used the PreserFlo MicroShunt. No studies using the XEN Gel Stent implantation met our criteria. The studies were conducted in North America, Europe, and Africa. Planned follow-up periods ranged from six months to five years. The studies were reported poorly, which limited our ability to judge risk of bias for many domains. None of the studies explicitly masked outcome assessment. We rated seven studies at high risk of detection bias. Low-certainty of evidence from five studies showed that using the Ex-PRESS plus trabeculectomy compared with standard trabeculectomy may be associated with a slightly lower IOP at one year (mean difference (MD) -1.76 mmHg, 95% confidence interval (CI) -2.81 to -0.70; 213 eyes). Moderate-certainty of evidence from one study showed that using the PreserFlo MicroShunt may be associated with a slightly higher IOP than standard trabeculectomy at one year (MD 3.20 mmHg, 95% CI 2.29 to 4.11). Participants who received standard trabeculectomy may have a higher risk of hypotony compared with those who received device-modified trabeculectomy, but the evidence is uncertain (RR 0.73, 95% CI 0.46 to 1.17; I² = 38%; P = 0.14). In the subgroup of participants who received the PreserFlo MicroShunt, there was a lower risk of developing hypotony or shallow anterior chamber compared with those receiving standard trabeculectomy (RR 0.44, 95% CI 0.25 to 0.79; 526 eyes). Device-modified trabeculectomy may lead to less subsequent cataract surgery within one year (RR 0.46, 95% CI 0.27 to 0.80; I² = 0%). AUTHORS' CONCLUSIONS: Use of an Ex-PRESS plus trabeculectomy may produce greater IOP reduction at one-year follow-up than standard trabeculectomy; however, due to potential biases and imprecision in effect estimates, the certainty of evidence is low. PreserFlo MicroShunt may be inferior to standard trabeculectomy in lowering IOP. However, PreserFlo MicroShunt may prevent postoperative hypotony and bleb leakage. Overall, device-modified trabeculectomy appears associated with a lower risk of cataract surgery within five years compared with standard trabeculectomy. Due to various limitations in the design and conduct of the included studies, the applicability of this evidence synthesis to other populations or settings is uncertain. Further research is needed to determine the effectiveness and safety of other devices in subgroup populations, such as people with different types of glaucoma, of various races and ethnicity, and with different lens types (e.g. phakic, pseudophakic).

Systematic review

Unclassified

Authors Wang L , Sha F , Guo DD , Bi HS , Si JK , Du YX , Tang K
Journal International journal of ophthalmology
Year 2016
Loading references information
AIM: To systematically review the current evidence based on the efficacy and cost of Ex-PRESS implantation and trabeculectomy (Trab) for uncontrolled glaucoma. METHODS: Clinical trials were identified by electronic databases (PubMed, EMBASE, ISI Web of science and Cochrane library), and data, such as intraocular pressure (IOP), the complete and qualified success rate, the postoperative complications and the cost, were exacted from these relevant studies. Weighted mean difference (WMD), odds ratio (OR) and 95% confidence intervals (CIs) were calculated and were pooled using a random-effects model. RESULTS: Eleven relevant publications and two abstracts met the inclusion criteria. The efficacy of Ex-PRESS was similar to that of Trab in the percentage of IOP reduction (IOPR %) at 1, 2y (WMD: -2.01; 95% CI: -7.92-3.90; P=0.50 and WMD: 2.89; 95% CI: -8.05-13.83; P=0.60, respectively). Ex-PRESS possessed a significant higher complete and qualified success rate (OR: 1.59; 95% CI: 1.07-2.35; P=0.02 and OR: 1.74; 95% CI: 1.06-2.86; P=0.03, respectively). Moreover, Ex-PRESS exerted a significantly lower frequency of hypotony and hyphema than Trab (OR: 0.39; 95% CI: 0.21-0.72; P=0.003 and OR: 0.27; 95% CI: 0.10-0.69; P=0.003, respectively). However, there was no consistent result on the cost between the two groups according to the previous three studies. CONCLUSION: Both Trab and Ex-PRESS have equivalent efficacy in lowering IOP, yet Ex-PRESS had a lower risk of hypotony and hyphema than Trab. Nevertheless, whether the cost of Ex-PRESS was less than that of Trab should be further investigated to ensure evidence-based conclusion in the long run. © 2016, International Journal of Ophthalmology (c/o Editorial Office). All right reserved.